Comparison of Simple Algorithms for Estimating Respiration Rate from Electrical Impedance Pneumography Signals in Wearable Devices

Research output: Contribution to journalArticleScientificpeer-review

Standard

Comparison of Simple Algorithms for Estimating Respiration Rate from Electrical Impedance Pneumography Signals in Wearable Devices. / Jeyhani, Vala; Vuorinen, Tiina; Mäntysalo, Matti; Vehkaoja, Antti.

In: HEALTH AND TECHNOLOGY, Vol. 7, No. 1, 2017, p. 21-31.

Research output: Contribution to journalArticleScientificpeer-review

Harvard

APA

Vancouver

Author

Bibtex - Download

@article{4787ad5b35e149eeaeae4c0028636c06,
title = "Comparison of Simple Algorithms for Estimating Respiration Rate from Electrical Impedance Pneumography Signals in Wearable Devices",
abstract = "Respiration rate (RR) is considered as a useful parameter in characterizing the health condition of a person. Among the methods used for respiration measurement, Electrical Impedance Pneumography (EIP) can be easily obtained in wearable applications due to the possibility of using the electrocardiography (ECG) electrodes for the EIP measurement. In the fast growing field of wearable devices, having clinically valuable and reliable information along with providing the convenience of the user, is probably the most important and challenging issue. To address the need of small sized devices for ECG (and EIP) measurements, EASI electrode configuration is an acceptable solution. The signals from EASI system not only provide useful information by themselves when directly used for cardiological analyses, but can also be converted to the standard 12-lead ECG information. With aforementioned advantages of EASI system, the question then arises how suitable the electrode locations of the system are for EIP measurements and what algorithms perform better for respiration rate derivation. In this work, we evaluated eight methods for deriving respiration rate from EIP signals measured from 15 subjects (10 males +5 females) in three conditions: standing, walking slowly, and walking fast. The algorithms were autoregressive (AR) modeling (three different approaches), Fast Fourier Transform (FFT), autocorrelation, peak detection and two counting algorithms. Our results show that advanced counting method is the most promising approach among the ones studied in this work. For this algorithm, the concordance correlation coefficients of the respiration rate estimates between EIP and the reference measurement were 0.96, 0.90 and 0.97 for standing, walking with 3 km/h speed, and walking with 6 km/h speed, respectively.",
author = "Vala Jeyhani and Tiina Vuorinen and Matti M{\"a}ntysalo and Antti Vehkaoja",
year = "2017",
doi = "10.1007/s12553-016-0156-0",
language = "English",
volume = "7",
pages = "21--31",
journal = "HEALTH AND TECHNOLOGY",
issn = "2190-7188",
publisher = "Springer Verlag",
number = "1",

}

RIS (suitable for import to EndNote) - Download

TY - JOUR

T1 - Comparison of Simple Algorithms for Estimating Respiration Rate from Electrical Impedance Pneumography Signals in Wearable Devices

AU - Jeyhani, Vala

AU - Vuorinen, Tiina

AU - Mäntysalo, Matti

AU - Vehkaoja, Antti

PY - 2017

Y1 - 2017

N2 - Respiration rate (RR) is considered as a useful parameter in characterizing the health condition of a person. Among the methods used for respiration measurement, Electrical Impedance Pneumography (EIP) can be easily obtained in wearable applications due to the possibility of using the electrocardiography (ECG) electrodes for the EIP measurement. In the fast growing field of wearable devices, having clinically valuable and reliable information along with providing the convenience of the user, is probably the most important and challenging issue. To address the need of small sized devices for ECG (and EIP) measurements, EASI electrode configuration is an acceptable solution. The signals from EASI system not only provide useful information by themselves when directly used for cardiological analyses, but can also be converted to the standard 12-lead ECG information. With aforementioned advantages of EASI system, the question then arises how suitable the electrode locations of the system are for EIP measurements and what algorithms perform better for respiration rate derivation. In this work, we evaluated eight methods for deriving respiration rate from EIP signals measured from 15 subjects (10 males +5 females) in three conditions: standing, walking slowly, and walking fast. The algorithms were autoregressive (AR) modeling (three different approaches), Fast Fourier Transform (FFT), autocorrelation, peak detection and two counting algorithms. Our results show that advanced counting method is the most promising approach among the ones studied in this work. For this algorithm, the concordance correlation coefficients of the respiration rate estimates between EIP and the reference measurement were 0.96, 0.90 and 0.97 for standing, walking with 3 km/h speed, and walking with 6 km/h speed, respectively.

AB - Respiration rate (RR) is considered as a useful parameter in characterizing the health condition of a person. Among the methods used for respiration measurement, Electrical Impedance Pneumography (EIP) can be easily obtained in wearable applications due to the possibility of using the electrocardiography (ECG) electrodes for the EIP measurement. In the fast growing field of wearable devices, having clinically valuable and reliable information along with providing the convenience of the user, is probably the most important and challenging issue. To address the need of small sized devices for ECG (and EIP) measurements, EASI electrode configuration is an acceptable solution. The signals from EASI system not only provide useful information by themselves when directly used for cardiological analyses, but can also be converted to the standard 12-lead ECG information. With aforementioned advantages of EASI system, the question then arises how suitable the electrode locations of the system are for EIP measurements and what algorithms perform better for respiration rate derivation. In this work, we evaluated eight methods for deriving respiration rate from EIP signals measured from 15 subjects (10 males +5 females) in three conditions: standing, walking slowly, and walking fast. The algorithms were autoregressive (AR) modeling (three different approaches), Fast Fourier Transform (FFT), autocorrelation, peak detection and two counting algorithms. Our results show that advanced counting method is the most promising approach among the ones studied in this work. For this algorithm, the concordance correlation coefficients of the respiration rate estimates between EIP and the reference measurement were 0.96, 0.90 and 0.97 for standing, walking with 3 km/h speed, and walking with 6 km/h speed, respectively.

U2 - 10.1007/s12553-016-0156-0

DO - 10.1007/s12553-016-0156-0

M3 - Article

VL - 7

SP - 21

EP - 31

JO - HEALTH AND TECHNOLOGY

JF - HEALTH AND TECHNOLOGY

SN - 2190-7188

IS - 1

ER -