Tampere University of Technology

TUTCRIS Research Portal

Depth profiling of PLGA copolymer in a novel biomedical bilayer using confocal raman spectroscopy

Research output: Contribution to journalArticleScientificpeer-review

Details

Original languageEnglish
Pages (from-to)5905-5910
Number of pages6
JournalLangmuir
Volume29
Issue number19
DOIs
Publication statusPublished - 14 May 2013
Publication typeA1 Journal article-refereed

Abstract

Confocal Raman spectroscopy was undertaken to identify separate layers of PLGA and gentamicin sulfate (GS) coatings on a titanium alloy substrate for a novel drug-delivery system. Additionally, it was found that it was possible to measure the layer thickness and uniformity of the PLGA accurately by detecting intensity and wavelength changes in the vibrational bands of the copolymer bonds. Further analysis of the materials was done using FIB, SEM/EDX, and profilometry; these techniques were used to confirm the findings of the Raman data. It was determined that the substrate was extremely rough and therefore the coating was not uniform in thickness but the materials were uniformly dispersed. Most importantly, two distinct GS and PLGA layers were present.