Tampere University of Technology

TUTCRIS Research Portal

Effect of Photovoltaic Generator Components on the Number of MPPs Under Partial Shading Conditions

Research output: Contribution to journalArticleScientificpeer-review

Details

Original languageEnglish
Pages (from-to)1008-1017
Number of pages10
JournalIEEE Transactions on Energy Conversion
Volume28
Issue number4
DOIs
Publication statusPublished - Dec 2013
Publication typeA1 Journal article-refereed

Abstract

Partial shading of photovoltaic (PV) power generators causes typically multiple maximum power points (MPPs) on the electrical characteristics of the generators. In this paper, the effect of partial shading on the number of MPPs has been studied by using MATLAB Simulink simulation models of a real PV generator composed of 18 series-connected PV modules. In most cases, partial shading conditions lead to the occurrence of multiple MPPs, but also only one MPP can be present despite of the partial shading. Conditions, which lead to one or multiple MPPs in electrical characteristics of PV generators, have been studied systematically. It was found out that reasons for having one or more MPPs originated directly from physical properties of PV modules: the ratio of MPP current to short-circuit current, power losses in bypass diodes, and the value of the parasitic shunt resistance of PV cells. These phenomena are thoroughly explained in this paper.

Keywords

  • Maximum power point (MPP), PV power systems, partial shading, photovoltaic (PV) cells, solar power generation, CURRENT-VOLTAGE CHARACTERISTICS, SHADED SOLAR-CELLS, ARRAYS, SIMULATION, MODEL, MISMATCH, LOSSES, MODULE

Publication forum classification