ESD qualification data used as the basis for building electrostatic discharge protected areas. / Tamminen, Pasi; Viheriäkoski, Toni; Sydänheimo, Lauri; Ukkonen, Leena.

In: Journal of Electrostatics, Vol. 77, 3024, 01.10.2015, p. 174-181.

Research output: Contribution to journalArticleScientificpeer-review

Harvard

APA

Vancouver

Author

Tamminen, Pasi ; Viheriäkoski, Toni ; Sydänheimo, Lauri ; Ukkonen, Leena. / ESD qualification data used as the basis for building electrostatic discharge protected areas. In: Journal of Electrostatics. 2015 ; Vol. 77. pp. 174-181.

Bibtex - Download

@article{95d645c14ff344f886528ed767494623,
title = "ESD qualification data used as the basis for building electrostatic discharge protected areas",
abstract = "ESD control programs that are based on the standards IEC61340-5-1 and ANSI/ESD S20.20 are targeted to provide safer handling of electronic parts now susceptible to damage by electrostatic discharge. However, ESD failures have occurred in EPA even when all standard control methods are met. To further improve EPAs, ESD control programs should be updated to cover all known common discharge scenarios, and multiple parallel ESD source parameters should be used to assess the level of ESD risks. In addition, a reliable ESD risk assessment should be based on discharge source circuit analysis and product sensitivity tests using the real discharge waveforms found in EPA.",
keywords = "CDM, Control program, EPA, ESD, HBM, Standards",
author = "Pasi Tamminen and Toni Viheri{\"a}koski and Lauri Syd{\"a}nheimo and Leena Ukkonen",
year = "2015",
month = "10",
day = "1",
doi = "10.1016/j.elstat.2015.08.009",
language = "English",
volume = "77",
pages = "174--181",
journal = "Journal of Electrostatics",
issn = "0304-3886",
publisher = "Elsevier Science B.V.",

}

RIS (suitable for import to EndNote) - Download

TY - JOUR

T1 - ESD qualification data used as the basis for building electrostatic discharge protected areas

AU - Tamminen, Pasi

AU - Viheriäkoski, Toni

AU - Sydänheimo, Lauri

AU - Ukkonen, Leena

PY - 2015/10/1

Y1 - 2015/10/1

N2 - ESD control programs that are based on the standards IEC61340-5-1 and ANSI/ESD S20.20 are targeted to provide safer handling of electronic parts now susceptible to damage by electrostatic discharge. However, ESD failures have occurred in EPA even when all standard control methods are met. To further improve EPAs, ESD control programs should be updated to cover all known common discharge scenarios, and multiple parallel ESD source parameters should be used to assess the level of ESD risks. In addition, a reliable ESD risk assessment should be based on discharge source circuit analysis and product sensitivity tests using the real discharge waveforms found in EPA.

AB - ESD control programs that are based on the standards IEC61340-5-1 and ANSI/ESD S20.20 are targeted to provide safer handling of electronic parts now susceptible to damage by electrostatic discharge. However, ESD failures have occurred in EPA even when all standard control methods are met. To further improve EPAs, ESD control programs should be updated to cover all known common discharge scenarios, and multiple parallel ESD source parameters should be used to assess the level of ESD risks. In addition, a reliable ESD risk assessment should be based on discharge source circuit analysis and product sensitivity tests using the real discharge waveforms found in EPA.

KW - CDM

KW - Control program

KW - EPA

KW - ESD

KW - HBM

KW - Standards

U2 - 10.1016/j.elstat.2015.08.009