Physical characteristics of collimators for dual-isotope imaging with 99mTc and 123I

Research output: Chapter in Book/Report/Conference proceedingConference contributionScientificpeer-review

Standard

Physical characteristics of collimators for dual-isotope imaging with 99mTc and 123I. / Tunninen, V.; Kauppinen, T.; Eskola, H.

EMBEC and NBC 2017 - Joint Conference of the European Medical and Biological Engineering Conference EMBEC 2017 and the Nordic-Baltic Conference on Biomedical Engineering and Medical Physics, NBC 2017. Springer Verlag, 2018. p. 245-249 (IFMBE Proceedings; Vol. 65).

Research output: Chapter in Book/Report/Conference proceedingConference contributionScientificpeer-review

Harvard

Tunninen, V, Kauppinen, T & Eskola, H 2018, Physical characteristics of collimators for dual-isotope imaging with 99mTc and 123I. in EMBEC and NBC 2017 - Joint Conference of the European Medical and Biological Engineering Conference EMBEC 2017 and the Nordic-Baltic Conference on Biomedical Engineering and Medical Physics, NBC 2017. IFMBE Proceedings, vol. 65, Springer Verlag, pp. 245-249, Joint Conference of the European Medical and Biological Engineering Conference (EMBEC) and the Nordic-Baltic Conference on Biomedical Engineering and Medical Physics (NBC), 1/01/00. https://doi.org/10.1007/978-981-10-5122-7_62

APA

Tunninen, V., Kauppinen, T., & Eskola, H. (2018). Physical characteristics of collimators for dual-isotope imaging with 99mTc and 123I. In EMBEC and NBC 2017 - Joint Conference of the European Medical and Biological Engineering Conference EMBEC 2017 and the Nordic-Baltic Conference on Biomedical Engineering and Medical Physics, NBC 2017 (pp. 245-249). (IFMBE Proceedings; Vol. 65). Springer Verlag. https://doi.org/10.1007/978-981-10-5122-7_62

Vancouver

Tunninen V, Kauppinen T, Eskola H. Physical characteristics of collimators for dual-isotope imaging with 99mTc and 123I. In EMBEC and NBC 2017 - Joint Conference of the European Medical and Biological Engineering Conference EMBEC 2017 and the Nordic-Baltic Conference on Biomedical Engineering and Medical Physics, NBC 2017. Springer Verlag. 2018. p. 245-249. (IFMBE Proceedings). https://doi.org/10.1007/978-981-10-5122-7_62

Author

Tunninen, V. ; Kauppinen, T. ; Eskola, H. / Physical characteristics of collimators for dual-isotope imaging with 99mTc and 123I. EMBEC and NBC 2017 - Joint Conference of the European Medical and Biological Engineering Conference EMBEC 2017 and the Nordic-Baltic Conference on Biomedical Engineering and Medical Physics, NBC 2017. Springer Verlag, 2018. pp. 245-249 (IFMBE Proceedings).

Bibtex - Download

@inproceedings{5c88b207a1b2492bbc555ed7d09fa3b0,
title = "Physical characteristics of collimators for dual-isotope imaging with 99mTc and 123I",
abstract = "The purpose of this study was to compare the physical characteristics of Low Energy High Resolution (LEHR), Low Energy Ultra High Resolution (LEUHR) and Medium Energy Low Penetration (MELP) collimators for simultaneous 99mTc and 123I imaging. MELP collimator performed well with 123I high-energy gamma photons, but low resolution makes it unsuitable to use for acquisition of small structures such as parathyroid adenomas. LEUHR collimators optimized for 99mTc have highest resolution, but the differences in septal penetration and sensitivity in favor of LEHR collimator needs to be tested with specific parathyroid phantoms.",
keywords = "I, Tc, Collimator, Dual-isotope, SPECT/CT",
author = "V. Tunninen and T. Kauppinen and H. Eskola",
note = "EXT={"}Tunninen, V.{"} jufoid=58152",
year = "2018",
doi = "10.1007/978-981-10-5122-7_62",
language = "English",
isbn = "9789811051210",
series = "IFMBE Proceedings",
publisher = "Springer Verlag",
pages = "245--249",
booktitle = "EMBEC and NBC 2017 - Joint Conference of the European Medical and Biological Engineering Conference EMBEC 2017 and the Nordic-Baltic Conference on Biomedical Engineering and Medical Physics, NBC 2017",
address = "Germany",

}

RIS (suitable for import to EndNote) - Download

TY - GEN

T1 - Physical characteristics of collimators for dual-isotope imaging with 99mTc and 123I

AU - Tunninen, V.

AU - Kauppinen, T.

AU - Eskola, H.

N1 - EXT="Tunninen, V." jufoid=58152

PY - 2018

Y1 - 2018

N2 - The purpose of this study was to compare the physical characteristics of Low Energy High Resolution (LEHR), Low Energy Ultra High Resolution (LEUHR) and Medium Energy Low Penetration (MELP) collimators for simultaneous 99mTc and 123I imaging. MELP collimator performed well with 123I high-energy gamma photons, but low resolution makes it unsuitable to use for acquisition of small structures such as parathyroid adenomas. LEUHR collimators optimized for 99mTc have highest resolution, but the differences in septal penetration and sensitivity in favor of LEHR collimator needs to be tested with specific parathyroid phantoms.

AB - The purpose of this study was to compare the physical characteristics of Low Energy High Resolution (LEHR), Low Energy Ultra High Resolution (LEUHR) and Medium Energy Low Penetration (MELP) collimators for simultaneous 99mTc and 123I imaging. MELP collimator performed well with 123I high-energy gamma photons, but low resolution makes it unsuitable to use for acquisition of small structures such as parathyroid adenomas. LEUHR collimators optimized for 99mTc have highest resolution, but the differences in septal penetration and sensitivity in favor of LEHR collimator needs to be tested with specific parathyroid phantoms.

KW - I

KW - Tc

KW - Collimator

KW - Dual-isotope

KW - SPECT/CT

U2 - 10.1007/978-981-10-5122-7_62

DO - 10.1007/978-981-10-5122-7_62

M3 - Conference contribution

SN - 9789811051210

T3 - IFMBE Proceedings

SP - 245

EP - 249

BT - EMBEC and NBC 2017 - Joint Conference of the European Medical and Biological Engineering Conference EMBEC 2017 and the Nordic-Baltic Conference on Biomedical Engineering and Medical Physics, NBC 2017

PB - Springer Verlag

ER -