Tampere University of Technology

TUTCRIS Research Portal

Stress relaxation in tempered glass caused by heat soak testing

Research output: Contribution to journalArticleScientificpeer-review

Details

Original languageEnglish
Pages (from-to)42-49
Number of pages8
JournalEngineering Structures
Volume122
DOIs
Publication statusPublished - 1 Sep 2016
Publication typeA1 Journal article-refereed

Abstract

Heat soak testing of tempered glass is a thermal process required after the tempering process itself to bring glasses of commercial soda-lime-silica-glass to failure that are contaminated with nickel sulphide inclusions, diameter 50 mm to 500 mm typically. Thus, the tests avoid a so-called "spontaneous" breakage of the glass in building elements at ambient temperatures months or years later. According to industry standards, the duration of the tests typically differs between 1 h and 4 h at temperatures of 290 ± 10 °C. Although this temperature is well below the transformation temperature of commercial soda-lime-silica glass, it causes stress relaxation in tempered glass and the fracture pattern of the glass changes accordingly, especially thin glasses are affected. Based on the Tool-Narayanaswamy-Model, this paper comprises the theoretical background of the stress-relaxation-process and the results of a parameter study for its most influential technical parameters. Results are compared to photoelastic measurements of temper stresses and fracture patterns of tempered glass before and after a heat treatment similar to heat soak testing.

ASJC Scopus subject areas

Keywords

  • Fracture pattern, Heat soak test, Photoelastic measurements, Stress relaxation, Tempered glass, Tool-Narayanaswamy-Model

Publication forum classification

Field of science, Statistics Finland