A communication based protection system for solving DG related protection challenges. / Raipala, Ontrei; Repo, Sami; Järventausta, Pertti.

23rd International Conference on Electricity Distribution, CIRED 2015. 2015. s. 1-5 0906 (International Conference and Exhibition on Electricity Distribution).

Tutkimustuotosvertaisarvioitu

Harvard

Raipala, O, Repo, S & Järventausta, P 2015, A communication based protection system for solving DG related protection challenges. julkaisussa 23rd International Conference on Electricity Distribution, CIRED 2015., 0906, International Conference and Exhibition on Electricity Distribution, Sivut 1-5, International Conference and Exhibition on Electricity Distribution, 1/01/00.

APA

Raipala, O., Repo, S., & Järventausta, P. (2015). A communication based protection system for solving DG related protection challenges. teoksessa 23rd International Conference on Electricity Distribution, CIRED 2015 (Sivut 1-5). [0906] (International Conference and Exhibition on Electricity Distribution).

Vancouver

Raipala O, Repo S, Järventausta P. A communication based protection system for solving DG related protection challenges. julkaisussa 23rd International Conference on Electricity Distribution, CIRED 2015. 2015. s. 1-5. 0906. (International Conference and Exhibition on Electricity Distribution).

Author

Raipala, Ontrei ; Repo, Sami ; Järventausta, Pertti. / A communication based protection system for solving DG related protection challenges. 23rd International Conference on Electricity Distribution, CIRED 2015. 2015. Sivut 1-5 (International Conference and Exhibition on Electricity Distribution).

Bibtex - Lataa

@inproceedings{7ccc64d357554de285337aaafc4e910c,
title = "A communication based protection system for solving DG related protection challenges",
abstract = "This paper presents a communication based protection automation system which is designed for solving DG related protection problems. The system is able to tackle problems related protection blinding, nuisance tripping of feeders and generators and problems related to unintentional islanding. Moreover, the system can be configured to allow low voltage ride-through without compromising loss of mains protection. However, the system also has the potential of enhancing the reliability of electricity distribution service to DG units by automatically switching an alternative feeding path if the original feeding route is faulted.",
author = "Ontrei Raipala and Sami Repo and Pertti J{\"a}rventausta",
year = "2015",
month = "6",
day = "15",
language = "English",
series = "International Conference and Exhibition on Electricity Distribution",
pages = "1--5",
booktitle = "23rd International Conference on Electricity Distribution, CIRED 2015",

}

RIS (suitable for import to EndNote) - Lataa

TY - GEN

T1 - A communication based protection system for solving DG related protection challenges

AU - Raipala, Ontrei

AU - Repo, Sami

AU - Järventausta, Pertti

PY - 2015/6/15

Y1 - 2015/6/15

N2 - This paper presents a communication based protection automation system which is designed for solving DG related protection problems. The system is able to tackle problems related protection blinding, nuisance tripping of feeders and generators and problems related to unintentional islanding. Moreover, the system can be configured to allow low voltage ride-through without compromising loss of mains protection. However, the system also has the potential of enhancing the reliability of electricity distribution service to DG units by automatically switching an alternative feeding path if the original feeding route is faulted.

AB - This paper presents a communication based protection automation system which is designed for solving DG related protection problems. The system is able to tackle problems related protection blinding, nuisance tripping of feeders and generators and problems related to unintentional islanding. Moreover, the system can be configured to allow low voltage ride-through without compromising loss of mains protection. However, the system also has the potential of enhancing the reliability of electricity distribution service to DG units by automatically switching an alternative feeding path if the original feeding route is faulted.

M3 - Conference contribution

T3 - International Conference and Exhibition on Electricity Distribution

SP - 1

EP - 5

BT - 23rd International Conference on Electricity Distribution, CIRED 2015

ER -