TUTCRIS - Tampereen teknillinen yliopisto

TUTCRIS

Absorbable plugs of self-reinforced poly-L-lactic acid in the internal fixation of rabbit distal femoral osteotomies

Tutkimustuotosvertaisarvioitu

Standard

Absorbable plugs of self-reinforced poly-L-lactic acid in the internal fixation of rabbit distal femoral osteotomies. / Pihlajamäki, H.; Böstman, O.; Manninen, M.; Päivärinta, U.; Törmälä, P.; Rokkanen, P.

julkaisussa: Clinical Orthopaedics, Nro 298, 1994, s. 277-285.

Tutkimustuotosvertaisarvioitu

Harvard

Pihlajamäki, H, Böstman, O, Manninen, M, Päivärinta, U, Törmälä, P & Rokkanen, P 1994, 'Absorbable plugs of self-reinforced poly-L-lactic acid in the internal fixation of rabbit distal femoral osteotomies', Clinical Orthopaedics, Nro 298, Sivut 277-285.

APA

Pihlajamäki, H., Böstman, O., Manninen, M., Päivärinta, U., Törmälä, P., & Rokkanen, P. (1994). Absorbable plugs of self-reinforced poly-L-lactic acid in the internal fixation of rabbit distal femoral osteotomies. Clinical Orthopaedics, (298), 277-285.

Vancouver

Pihlajamäki H, Böstman O, Manninen M, Päivärinta U, Törmälä P, Rokkanen P. Absorbable plugs of self-reinforced poly-L-lactic acid in the internal fixation of rabbit distal femoral osteotomies. Clinical Orthopaedics. 1994;(298):277-285.

Author

Pihlajamäki, H. ; Böstman, O. ; Manninen, M. ; Päivärinta, U. ; Törmälä, P. ; Rokkanen, P. / Absorbable plugs of self-reinforced poly-L-lactic acid in the internal fixation of rabbit distal femoral osteotomies. Julkaisussa: Clinical Orthopaedics. 1994 ; Nro 298. Sivut 277-285.

Bibtex - Lataa

@article{9beb902bb05f43dd9e4d1361d1f436a4,
title = "Absorbable plugs of self-reinforced poly-L-lactic acid in the internal fixation of rabbit distal femoral osteotomies",
author = "H. Pihlajam{\"a}ki and O. B{\"o}stman and M. Manninen and U. P{\"a}iv{\"a}rinta and P. T{\"o}rm{\"a}l{\"a} and P. Rokkanen",
note = "Contribution: organisation=mol muo,FACT1=1",
year = "1994",
language = "English",
pages = "277--285",
journal = "Clinical Orthopaedics",
number = "298",

}

RIS (suitable for import to EndNote) - Lataa

TY - JOUR

T1 - Absorbable plugs of self-reinforced poly-L-lactic acid in the internal fixation of rabbit distal femoral osteotomies

AU - Pihlajamäki, H.

AU - Böstman, O.

AU - Manninen, M.

AU - Päivärinta, U.

AU - Törmälä, P.

AU - Rokkanen, P.

N1 - Contribution: organisation=mol muo,FACT1=1

PY - 1994

Y1 - 1994

M3 - Article

SP - 277

EP - 285

JO - Clinical Orthopaedics

JF - Clinical Orthopaedics

IS - 298

ER -