TUTCRIS - Tampereen teknillinen yliopisto

TUTCRIS

Energy Efficient Measurement and Signal Processing for Self-powered, Lamb-wave-based Structural Health Monitoring System

Tutkimustuotos

Standard

Energy Efficient Measurement and Signal Processing for Self-powered, Lamb-wave-based Structural Health Monitoring System. / Hytti, Heli.

Tampere : Tampere University of Technology, 2010. 178 s. (Tampere University of Technology. Publication; Vuosikerta 916).

Tutkimustuotos

Harvard

Hytti, H 2010, Energy Efficient Measurement and Signal Processing for Self-powered, Lamb-wave-based Structural Health Monitoring System. Tampere University of Technology. Publication, Vuosikerta. 916, Tampere University of Technology, Tampere.

APA

Hytti, H. (2010). Energy Efficient Measurement and Signal Processing for Self-powered, Lamb-wave-based Structural Health Monitoring System. (Tampere University of Technology. Publication; Vuosikerta 916). Tampere: Tampere University of Technology.

Vancouver

Hytti H. Energy Efficient Measurement and Signal Processing for Self-powered, Lamb-wave-based Structural Health Monitoring System. Tampere: Tampere University of Technology, 2010. 178 s. (Tampere University of Technology. Publication).

Author

Hytti, Heli. / Energy Efficient Measurement and Signal Processing for Self-powered, Lamb-wave-based Structural Health Monitoring System. Tampere : Tampere University of Technology, 2010. 178 Sivumäärä (Tampere University of Technology. Publication).

Bibtex - Lataa

@book{1ecfe162021a406589a4fb303257c5e3,
title = "Energy Efficient Measurement and Signal Processing for Self-powered, Lamb-wave-based Structural Health Monitoring System",
abstract = "Ultrasonic waves have been applied in non-destructive testing for decades. Development of new sensors and transducers for actuating and detecting the ultrasonic guided waves has made the ultrasonic structural health monitoring more viable both technically and economically than it has been in the past. However, from both the economical and technical point of view, the wiring needed for powering the measurement system and transferring the collected data is seldom acceptable. The demand for wireless and self-powered, energy efficient systems is continuously increasing. This thesis contributes to development of a structural health monitoring system suitable for continuous use in industrial applications. The suggested monitoring system integrates a well-known piezoelectric actuator and sensor technique for Lamb wave based defect detection with wireless data transfer, power harvesting and data analysis in an affordable manner. Low power production in the local power harvesting dominates the design of both the components and the operating principle of the integrated system. The main contributions of this thesis are 1) specifications for a new, energy efficient measurement system, where only a few key samples are measured from the piezoelectric transducer response to ultrasonic guided waves and the response is then reconstructed from these samples, 2) repeatability analysis of the measurements and the defect indicating parameters calculated from them, and 3) enhanced defect detection and location method based on changes in variance of the response and the repeatability of defect location. The defect location method is based on the reconstruction algorithm for probabilistic inspection of defects suggested by Zhao et al. [Zha2007a] and developed further for improved function with small number of piezoelectric transducers and minimized amount of measurement data.",
author = "Heli Hytti",
note = "Awarding institution:Tampere University of Technology",
year = "2010",
month = "11",
day = "12",
language = "English",
isbn = "978-952-15-2443-1",
series = "Tampere University of Technology. Publication",
publisher = "Tampere University of Technology",

}

RIS (suitable for import to EndNote) - Lataa

TY - BOOK

T1 - Energy Efficient Measurement and Signal Processing for Self-powered, Lamb-wave-based Structural Health Monitoring System

AU - Hytti, Heli

N1 - Awarding institution:Tampere University of Technology

PY - 2010/11/12

Y1 - 2010/11/12

N2 - Ultrasonic waves have been applied in non-destructive testing for decades. Development of new sensors and transducers for actuating and detecting the ultrasonic guided waves has made the ultrasonic structural health monitoring more viable both technically and economically than it has been in the past. However, from both the economical and technical point of view, the wiring needed for powering the measurement system and transferring the collected data is seldom acceptable. The demand for wireless and self-powered, energy efficient systems is continuously increasing. This thesis contributes to development of a structural health monitoring system suitable for continuous use in industrial applications. The suggested monitoring system integrates a well-known piezoelectric actuator and sensor technique for Lamb wave based defect detection with wireless data transfer, power harvesting and data analysis in an affordable manner. Low power production in the local power harvesting dominates the design of both the components and the operating principle of the integrated system. The main contributions of this thesis are 1) specifications for a new, energy efficient measurement system, where only a few key samples are measured from the piezoelectric transducer response to ultrasonic guided waves and the response is then reconstructed from these samples, 2) repeatability analysis of the measurements and the defect indicating parameters calculated from them, and 3) enhanced defect detection and location method based on changes in variance of the response and the repeatability of defect location. The defect location method is based on the reconstruction algorithm for probabilistic inspection of defects suggested by Zhao et al. [Zha2007a] and developed further for improved function with small number of piezoelectric transducers and minimized amount of measurement data.

AB - Ultrasonic waves have been applied in non-destructive testing for decades. Development of new sensors and transducers for actuating and detecting the ultrasonic guided waves has made the ultrasonic structural health monitoring more viable both technically and economically than it has been in the past. However, from both the economical and technical point of view, the wiring needed for powering the measurement system and transferring the collected data is seldom acceptable. The demand for wireless and self-powered, energy efficient systems is continuously increasing. This thesis contributes to development of a structural health monitoring system suitable for continuous use in industrial applications. The suggested monitoring system integrates a well-known piezoelectric actuator and sensor technique for Lamb wave based defect detection with wireless data transfer, power harvesting and data analysis in an affordable manner. Low power production in the local power harvesting dominates the design of both the components and the operating principle of the integrated system. The main contributions of this thesis are 1) specifications for a new, energy efficient measurement system, where only a few key samples are measured from the piezoelectric transducer response to ultrasonic guided waves and the response is then reconstructed from these samples, 2) repeatability analysis of the measurements and the defect indicating parameters calculated from them, and 3) enhanced defect detection and location method based on changes in variance of the response and the repeatability of defect location. The defect location method is based on the reconstruction algorithm for probabilistic inspection of defects suggested by Zhao et al. [Zha2007a] and developed further for improved function with small number of piezoelectric transducers and minimized amount of measurement data.

M3 - Doctoral thesis

SN - 978-952-15-2443-1

T3 - Tampere University of Technology. Publication

BT - Energy Efficient Measurement and Signal Processing for Self-powered, Lamb-wave-based Structural Health Monitoring System

PB - Tampere University of Technology

CY - Tampere

ER -