Measurement of sensitivity distribution map of a ferroelectret polymer film

Tutkimustuotosvertaisarvioitu

Yksityiskohdat

AlkuperäiskieliEnglanti
Sivut8517-8522
JulkaisuIEEE Sensors Journal
Vuosikerta16
Numero23
DOI - pysyväislinkit
TilaJulkaistu - 27 syyskuuta 2016
OKM-julkaisutyyppiA1 Alkuperäisartikkeli

Tiivistelmä

ElectroMechanical Film (EMFi) is an electroactive ferroelectret polymer film with a special cellular structure. Sensitivity distribution maps of EMFi sensors were measured in this study. Seven EMFi sensors with evaporated gold electrodes, size 55 mm x 55 mm, were measured with a measurement grid spacing of 5 mm. The sensitivity is defined here as the charge generated by the EMFi sensor divided by the force applied to excite the sensor, and this is closely related to piezoelectric d33 coefficient. The sensitivity of EMFi was found to vary in different places of the sensors and between the measured sensors. This is presumably due to the relatively large gas voids and local corona breakdowns. The maximum and minimum sensitivities were found to vary around 30 % from the measured average sensitivity value. Thermally stimulated current (TSC) analysis confirmed the results obtained in the sensitivity distribution map measurements.