TUTCRIS - Tampereen teknillinen yliopisto

TUTCRIS

Performance evaluation of the sizing capabilities of a new diffusion charging based particle sensor

Tutkimustuotos: Konferenssiesitys, posteri tai abstrakti

Standard

Performance evaluation of the sizing capabilities of a new diffusion charging based particle sensor. / Salo, Laura; Gao, Jian; Saari, Sampo; Saukko, Erkka; Janka, Kauko; Rönkkö, Topi; Keskinen, Jorma.

2017. Julkaisun esittämispaikka: European Aerosol Conference 2017, Zürich, Sveitsi.

Tutkimustuotos: Konferenssiesitys, posteri tai abstrakti

Harvard

Salo, L, Gao, J, Saari, S, Saukko, E, Janka, K, Rönkkö, T & Keskinen, J 2017, 'Performance evaluation of the sizing capabilities of a new diffusion charging based particle sensor' Artikkeli esitetty, Zürich, Sveitsi, 27/08/17 - 1/09/17, .

APA

Salo, L., Gao, J., Saari, S., Saukko, E., Janka, K., Rönkkö, T., & Keskinen, J. (2017). Performance evaluation of the sizing capabilities of a new diffusion charging based particle sensor. Julkaisun esittämispaikka: European Aerosol Conference 2017, Zürich, Sveitsi.

Vancouver

Salo L, Gao J, Saari S, Saukko E, Janka K, Rönkkö T et al. Performance evaluation of the sizing capabilities of a new diffusion charging based particle sensor. 2017. Julkaisun esittämispaikka: European Aerosol Conference 2017, Zürich, Sveitsi.

Author

Salo, Laura ; Gao, Jian ; Saari, Sampo ; Saukko, Erkka ; Janka, Kauko ; Rönkkö, Topi ; Keskinen, Jorma. / Performance evaluation of the sizing capabilities of a new diffusion charging based particle sensor. Julkaisun esittämispaikka: European Aerosol Conference 2017, Zürich, Sveitsi.

Bibtex - Lataa

@conference{ac4f24f3c2b5437bb9175165ee15d07c,
title = "Performance evaluation of the sizing capabilities of a new diffusion charging based particle sensor",
abstract = "Pegasor’s AQ Indoor sensor (AQI) uses a newmethod for evaluating the count median diameter(CMD) of an aerosol (Saukko, 2016). A modified iontrap cycles voltages from 1 to 1000 V, trappingcharged particles along with ions. The larger theparticles, the lower their electrical mobility and thelarger the trap voltage needed to remove them.",
author = "Laura Salo and Jian Gao and Sampo Saari and Erkka Saukko and Kauko Janka and Topi R{\"o}nkk{\"o} and Jorma Keskinen",
year = "2017",
month = "8",
day = "28",
language = "English",
note = "European Aerosol Conference 2017 ; Conference date: 27-08-2017 Through 01-09-2017",

}

RIS (suitable for import to EndNote) - Lataa

TY - CONF

T1 - Performance evaluation of the sizing capabilities of a new diffusion charging based particle sensor

AU - Salo, Laura

AU - Gao, Jian

AU - Saari, Sampo

AU - Saukko, Erkka

AU - Janka, Kauko

AU - Rönkkö, Topi

AU - Keskinen, Jorma

PY - 2017/8/28

Y1 - 2017/8/28

N2 - Pegasor’s AQ Indoor sensor (AQI) uses a newmethod for evaluating the count median diameter(CMD) of an aerosol (Saukko, 2016). A modified iontrap cycles voltages from 1 to 1000 V, trappingcharged particles along with ions. The larger theparticles, the lower their electrical mobility and thelarger the trap voltage needed to remove them.

AB - Pegasor’s AQ Indoor sensor (AQI) uses a newmethod for evaluating the count median diameter(CMD) of an aerosol (Saukko, 2016). A modified iontrap cycles voltages from 1 to 1000 V, trappingcharged particles along with ions. The larger theparticles, the lower their electrical mobility and thelarger the trap voltage needed to remove them.

M3 - Paper, poster or abstract

ER -