TUTCRIS - Tampereen teknillinen yliopisto

TUTCRIS

Photovoltaic mismatch losses caused by moving clouds

Tutkimustuotosvertaisarvioitu

Standard

Photovoltaic mismatch losses caused by moving clouds. / Lappalainen, Kari; Valkealahti, Seppo.

julkaisussa: Solar Energy, Vuosikerta 158, 2017, s. 455-461.

Tutkimustuotosvertaisarvioitu

Harvard

APA

Vancouver

Author

Lappalainen, Kari ; Valkealahti, Seppo. / Photovoltaic mismatch losses caused by moving clouds. Julkaisussa: Solar Energy. 2017 ; Vuosikerta 158. Sivut 455-461.

Bibtex - Lataa

@article{a151131e01524954b194f4cb04a5a62e,
title = "Photovoltaic mismatch losses caused by moving clouds",
abstract = "Mismatch losses is a major issue in the photovoltaic (PV) system and are mainly caused by partial shading; largest mismatch losses are caused by sharp shadows. These shadows are a typical problem for rooftop and residential installations. In large-scale PV plants, partial shading is mostly caused by moving clouds which produce gentle irradiance transitions causing typically only minor irradiance differences between adjacent PV modules.This paper presents a study of the mismatch losses of PV arrays with various layouts and electrical configurations during around 27,000 irradiance transitions identified in measured irradiance data. The overall effect of the mismatch losses caused by moving clouds on the energy production of PV plants was also studied. The study was conducted using a mathematical model of irradiance transitions and an experimentally verified MATLAB/Simulink model of a PV module.The relative mismatch losses during the identified irradiance transitions ranged from 1.4{\%} to 4.0{\%} depending on the electrical configuration and layout of the PV array. The overall effect of the mismatch losses caused by moving clouds on the total electricity production of PV arrays was about 0.5{\%} for the PV array with strings of 28 PV modules and substantially smaller for arrays with shorter strings. The proportions of the total mismatch losses caused by very dark or highly transparent clouds were small. About 70{\%} of the total mismatch losses were caused by shadow edges with shading strengths ranging between 40{\%} and 80{\%}. These results indicate that the mismatch losses caused by moving clouds are not a major problem for large-scale PV plants. An interesting finding from a practical point of view is that the mismatch losses increase the rate of power fluctuations compared to the rate of irradiance fluctuations.",
author = "Kari Lappalainen and Seppo Valkealahti",
year = "2017",
doi = "10.1016/j.solener.2017.10.001",
language = "English",
volume = "158",
pages = "455--461",
journal = "Solar Energy",
issn = "0038-092X",
publisher = "Elsevier",

}

RIS (suitable for import to EndNote) - Lataa

TY - JOUR

T1 - Photovoltaic mismatch losses caused by moving clouds

AU - Lappalainen, Kari

AU - Valkealahti, Seppo

PY - 2017

Y1 - 2017

N2 - Mismatch losses is a major issue in the photovoltaic (PV) system and are mainly caused by partial shading; largest mismatch losses are caused by sharp shadows. These shadows are a typical problem for rooftop and residential installations. In large-scale PV plants, partial shading is mostly caused by moving clouds which produce gentle irradiance transitions causing typically only minor irradiance differences between adjacent PV modules.This paper presents a study of the mismatch losses of PV arrays with various layouts and electrical configurations during around 27,000 irradiance transitions identified in measured irradiance data. The overall effect of the mismatch losses caused by moving clouds on the energy production of PV plants was also studied. The study was conducted using a mathematical model of irradiance transitions and an experimentally verified MATLAB/Simulink model of a PV module.The relative mismatch losses during the identified irradiance transitions ranged from 1.4% to 4.0% depending on the electrical configuration and layout of the PV array. The overall effect of the mismatch losses caused by moving clouds on the total electricity production of PV arrays was about 0.5% for the PV array with strings of 28 PV modules and substantially smaller for arrays with shorter strings. The proportions of the total mismatch losses caused by very dark or highly transparent clouds were small. About 70% of the total mismatch losses were caused by shadow edges with shading strengths ranging between 40% and 80%. These results indicate that the mismatch losses caused by moving clouds are not a major problem for large-scale PV plants. An interesting finding from a practical point of view is that the mismatch losses increase the rate of power fluctuations compared to the rate of irradiance fluctuations.

AB - Mismatch losses is a major issue in the photovoltaic (PV) system and are mainly caused by partial shading; largest mismatch losses are caused by sharp shadows. These shadows are a typical problem for rooftop and residential installations. In large-scale PV plants, partial shading is mostly caused by moving clouds which produce gentle irradiance transitions causing typically only minor irradiance differences between adjacent PV modules.This paper presents a study of the mismatch losses of PV arrays with various layouts and electrical configurations during around 27,000 irradiance transitions identified in measured irradiance data. The overall effect of the mismatch losses caused by moving clouds on the energy production of PV plants was also studied. The study was conducted using a mathematical model of irradiance transitions and an experimentally verified MATLAB/Simulink model of a PV module.The relative mismatch losses during the identified irradiance transitions ranged from 1.4% to 4.0% depending on the electrical configuration and layout of the PV array. The overall effect of the mismatch losses caused by moving clouds on the total electricity production of PV arrays was about 0.5% for the PV array with strings of 28 PV modules and substantially smaller for arrays with shorter strings. The proportions of the total mismatch losses caused by very dark or highly transparent clouds were small. About 70% of the total mismatch losses were caused by shadow edges with shading strengths ranging between 40% and 80%. These results indicate that the mismatch losses caused by moving clouds are not a major problem for large-scale PV plants. An interesting finding from a practical point of view is that the mismatch losses increase the rate of power fluctuations compared to the rate of irradiance fluctuations.

U2 - 10.1016/j.solener.2017.10.001

DO - 10.1016/j.solener.2017.10.001

M3 - Article

VL - 158

SP - 455

EP - 461

JO - Solar Energy

JF - Solar Energy

SN - 0038-092X

ER -