TUTCRIS - Tampereen teknillinen yliopisto

TUTCRIS

Time and frequency-domain evidence on power quality issues caused by grid-connected three-phase photovoltaic inverters

Tutkimustuotosvertaisarvioitu

Standard

Time and frequency-domain evidence on power quality issues caused by grid-connected three-phase photovoltaic inverters. / Messo, T.; Jokipii, J.; Aapro, A.; Suntio, T.

EPE 14-ECCE Europe, the 16th European Conference on Power Electronics and Applications, 26-28 August 2014, Lappeenranta, Finland. Piscataway, NJ : Institute of Electrical and Electronics Engineers IEEE, 2014. s. 1-9.

Tutkimustuotosvertaisarvioitu

Harvard

Messo, T, Jokipii, J, Aapro, A & Suntio, T 2014, Time and frequency-domain evidence on power quality issues caused by grid-connected three-phase photovoltaic inverters. julkaisussa EPE 14-ECCE Europe, the 16th European Conference on Power Electronics and Applications, 26-28 August 2014, Lappeenranta, Finland. Institute of Electrical and Electronics Engineers IEEE, Piscataway, NJ, Sivut 1-9, EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, 1/01/00. https://doi.org/10.1109/EPE.2014.6910808

APA

Messo, T., Jokipii, J., Aapro, A., & Suntio, T. (2014). Time and frequency-domain evidence on power quality issues caused by grid-connected three-phase photovoltaic inverters. teoksessa EPE 14-ECCE Europe, the 16th European Conference on Power Electronics and Applications, 26-28 August 2014, Lappeenranta, Finland (Sivut 1-9). Piscataway, NJ: Institute of Electrical and Electronics Engineers IEEE. https://doi.org/10.1109/EPE.2014.6910808

Vancouver

Messo T, Jokipii J, Aapro A, Suntio T. Time and frequency-domain evidence on power quality issues caused by grid-connected three-phase photovoltaic inverters. julkaisussa EPE 14-ECCE Europe, the 16th European Conference on Power Electronics and Applications, 26-28 August 2014, Lappeenranta, Finland. Piscataway, NJ: Institute of Electrical and Electronics Engineers IEEE. 2014. s. 1-9 https://doi.org/10.1109/EPE.2014.6910808

Author

Messo, T. ; Jokipii, J. ; Aapro, A. ; Suntio, T. / Time and frequency-domain evidence on power quality issues caused by grid-connected three-phase photovoltaic inverters. EPE 14-ECCE Europe, the 16th European Conference on Power Electronics and Applications, 26-28 August 2014, Lappeenranta, Finland. Piscataway, NJ : Institute of Electrical and Electronics Engineers IEEE, 2014. Sivut 1-9

Bibtex - Lataa

@inproceedings{a07178f096f5439a91984dc5329279db,
title = "Time and frequency-domain evidence on power quality issues caused by grid-connected three-phase photovoltaic inverters",
author = "T. Messo and J. Jokipii and A. Aapro and T. Suntio",
note = "Contribution: organisation=dee,FACT1=1<br/>Portfolio EDEND: 2014-10-31",
year = "2014",
doi = "10.1109/EPE.2014.6910808",
language = "English",
isbn = "978-1-4799-3014-2",
pages = "1--9",
booktitle = "EPE 14-ECCE Europe, the 16th European Conference on Power Electronics and Applications, 26-28 August 2014, Lappeenranta, Finland",
publisher = "Institute of Electrical and Electronics Engineers IEEE",

}

RIS (suitable for import to EndNote) - Lataa

TY - GEN

T1 - Time and frequency-domain evidence on power quality issues caused by grid-connected three-phase photovoltaic inverters

AU - Messo, T.

AU - Jokipii, J.

AU - Aapro, A.

AU - Suntio, T.

N1 - Contribution: organisation=dee,FACT1=1<br/>Portfolio EDEND: 2014-10-31

PY - 2014

Y1 - 2014

U2 - 10.1109/EPE.2014.6910808

DO - 10.1109/EPE.2014.6910808

M3 - Conference contribution

SN - 978-1-4799-3014-2

SP - 1

EP - 9

BT - EPE 14-ECCE Europe, the 16th European Conference on Power Electronics and Applications, 26-28 August 2014, Lappeenranta, Finland

PB - Institute of Electrical and Electronics Engineers IEEE

CY - Piscataway, NJ

ER -